IGBT controlled Static Voltage Stabilizer

WORKING 

Encon QUIKorrect , IGBT based PWM type static voltage stabilizer only the difference voltage is switched through IGBT and will be added or subtracted from the mains. This is done electronically without any step changing in voltage which occurs when the system regulates. This is achieved by a feedback control system using digital signal processor (DSP). The output voltage is sensed by the DSP and corrections are made by varying the duty cycle of the PWM at 20KHZ and correction speed 20000/second. 

This stabilizer boosts up the voltage if it is low and bucks the voltage if it is high.

 

Highlights of QUIKorrect: 

* Instantaneous correction speed – over 20000V/second 

* Discrete IGBT up to 30KVA 1PH and 90KVA 3PH 

Module IGBT up to 70KVA 1PH and 210KVA 3PH 

* Single PCB for control stage, IGBT driver section and power stage 

* RFI, EMI and Surge Protector inbuilt 

* Single contactor for three phase system 

* Single LCD for three phases 

* RS 485/Bluetooth connectivity 

* Output Voltage Regulation – +/- 1% 

* Automatic Bypass 

* All protections included – low voltage, high voltage, overload, short circuit over temperature, phase reverse and phase fail 

 

Specifications

                                                                                                                              Specification

Particulars

Single Phase

Three Phase

Capacities

Discreet IGBT based

IGBT module based

1KVA to 30KVA

30KVA to 70KVA

3KVA to 90KVA

90KVA to 200KVA

Control type

DSP based IGBT PWM switching

DSP based IGBT PWM switching

Input Voltage Range for 220V output 

Normal

Wide

Extended

Input Voltage Range for 110V output 

Normal

Wide

Extended

180V to 260V

150V to 290V

90V to 300V

90V to 130V

75V to 145V

45V to 175V

312V to 450V

260V to 500V

155V to 520V

155V to 225V

130V to 250V

78V to 300V

Output Voltage

220V +/- 1% settable

110V +/- 1% settable

380V +/- 1% settable

190V +/- 1% settable

Regulation

+/- 1%

+/- 1%

Efficiency

> 97%

>97%

Input Frequency

45Hz to 65Hz

45Hz to 65Hz

Wave Form

Same as Input

Same as Input

Effect of Power factor

nil

nil

Display

LCD for Input voltage Output voltage Load VA

Line frequency

Overload

High voltage input

Low voltage input

Cut off mode

Bypass mode

Set up mode

Name of your company

LCD for 

Input voltage

Output voltage Load VA

Line frequency

Overload

High voltage input

Low voltage input

Cut off mode

Bypass mode

Set up mode

Name of your company

Rate of Correction

20000V/second

20000V/second

Operating Temperature

0 – 50°C

0 – 50° C

Duty cycle

Continuous

Continuous

Nature of Cooling

Air cooled

Air cooled

Mains bypass

Auto bypass to mains when stabilizer is on cut off mode and mains input voltage is between 190V to 250V.

Auto bypass to mains when stabilizer is on cut off mode and mains input voltage is between 190V to 250V.

Protections

Overload

Short circuit

High voltage

Low voltage

Overload

Short circuit

High voltage

Low voltage

Trip and restart

auto

auto

   
Scroll to Top